COVIDIEN FORCE FX PDF

It is intended as a guide for using the Valleylab Force FX™-C. Electrosurgical Generator only. Additional technical information is available in the Force FX™-C . Description. The Valleylab Force FX™ with Instant Response™ technology provides surgeons with improved performance at lower power settings, minimizing. The Force FX™ generator provides surgeons with the advantage of accurately direct cable link. • Valleylab VLCM bipolar current monitor.

Author: Yozshutaur Voodookazahn
Country: Vietnam
Language: English (Spanish)
Genre: Marketing
Published (Last): 9 December 2013
Pages: 305
PDF File Size: 9.31 Mb
ePub File Size: 14.59 Mb
ISBN: 187-8-25071-326-7
Downloads: 73511
Price: Free* [*Free Regsitration Required]
Uploader: Tygobar

Shop All Equine Equipment. Shop All Infusion Pumps.

Shop All Medical Gas. Shop All Research Equipment. Shop All Stainless Steel.

Valleylab Force FX-8 Electrosurgical Electrosurgery Unit

Shop All Surgical Lights. Shop All Telemetry Systems. Shop All Warming Units.

This reduction is achieved by limiting the RMS voltage and the high frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.

  LESTER THUROW HEAD TO HEAD PDF

PER indicates the ability of a generator to accurately deliver the selected power ccovidien a wide range of tissue types. When a conventional generator encounters tissue changes, both power delivery and cutting efficiency are reduced. This means that higher power settings are required in order to cut through all types of tissue. With higher power settings, more energy is delivered, and tissue damage increases.

Covidien ValleyLab Force Fx Electrosurgical Unit

Equipment Supplies There are currently no items in your cart. Call us toll-free Follow us: Output is further modulated by random Hz envelope with a variable duty cycle. Maximum current is 7 amperes in Cut and 4 amperes in Coag. High Frequency Leakage Bipolar: Less than 60 mA rms Monopolar: Covididn than 10 A Acceptable Resistance Ranges: For example, if the baseline impedance is 30 ohms, the upper level trip approximately 42 ohms.

ValleyLab Force FX – Refurbished

If the pad-patient impedance falls below the baseline impedance, a new baseline is established. Output Characteristics Precise Mode: Give Us A Call National toll-free number Password Forgot your password?